Portfolio
Touchmedix TouchED
- Demographics (ADT)
- Created an interface that allows for the transfer of
Emergency Department and Urgent Care patient demographic information
created with-in Soarian Financials to be available.
- TPC/IP Connections, HL7 ADT Message Type
- Discharge Summary Reports
- PDF document export - created an interface to encrypt the report,
and zip it into a daily file and transfer the patient data at a
specific time to the secondary billing office.
- FTP Connections, Flat File transfer, pgp encryption,
- RTF document export - created an interface to move the report
file to a daily archive folder on a network share.
- FTP Connections, Flat File transfer
- Plain txt document export - created an interface to move the report
file to the Siemens EDM application upload directory for processing.
- FTP Connections, Flat File transfer
- Siemens Imaging (EDM)
- Configured the EDM application to extract the appropriate data
from the imported discharge report to file the data appropriately
to the patient EDM record and allow for routing of the hyperlink
to the patient Soarian Clinical record.
- TPC/IP Connections, HL7 ORU Message Type